Installing IP500/IP500 V2
Page 276
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
10.9.6 So8
The So8 module is used to add ETSI BRI S0-interface ports to the IP Office system. These ports can then be used for the
connection of ISDN devices.
Feature
Details
Supported on
All IP Office control units except Small Office Edition.
Locales
Supported in all
IP Office locales
.
Software Level
IP Office core software level 1.0 minimum. Bin file = nas0-16.bin.
Included
Power supply unit (see below) and Expansion Interconnect cable.
Power Supply
The unit is supplied with an earthed 3-Pin, 60W external power supply unit. The PSU has an integral
power cord for connection to the unit's DC I/P socket. A locale specific
IEC60320 C13 power cord
for the external PSU is required but is not supplied with the unit.
·
Older units were supplied with a 2-Pin, 40W external power supply unit which used a locale
specific locale specific
IEC60320 C7 power cord
.
Mounting
The module is designed as a free-standing module that can be stacked on or under other IP Office
modules. The module can be rack mounted in a 19" rack system using the optional IP400 Rack
Mounting Kit.
Dimensions
Width: 445mm/17.5". Depth: 245mm/9.7". Height: 71mm/2.8"/2U.
Weight
Unboxed: 2.8Kg/6.3lbs. Boxed: 4.1Kg/9.2lbs.
Module Front
51
39
39
Summary of Contents for IP500
Page 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Page 10: ......
Page 12: ......
Page 58: ......
Page 120: ......
Page 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 422: ......
Page 434: ......
Page 440: ......
Page 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...