Installing IP500/IP500 V2
Page 151
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
Additional Processes: Changing Components
8.3.5 Permanent Removal
If permanently removing the component, the configuration will need to be edited to remove redundant trunk or extension/
user entries.
To permanently remove a component
1.
Shutdown the system
.
2. Switch off power to the system.
3. Remove the card or external expansion module.
4. Restart the IP Office system.
5. Use IP Office Manager to delete the trunks or extensions/users in the configuration that relate to the component
removed.
6. In the Control Unit section of the configuration, delete the entry for the component that is no longer present in the
system.
8.3.6 Replacemnt with a Different Type
If replacing a component with one of a different type, the process should be divided into two stages.
1. First remove the existing component using the
Permanent Removal
process and adjust the configuration and
reboot.
2. Then install the new component using the
Adding a New Component
process.