8.13 Reset Button
The IP500 and IP500 V2 control units have a Reset button. Pressing the button while the control unit is starting up will
pause the start up until the button is released. The effect of pressing the button during normal operation will depend on
how long the button is pressed and is indicated by the CPU LED.
Press Duration
(seconds)
CPU LED
Action
Summary
0 to 5.
Off
None
None.
5 to 10.
Orange
Reboot When Free
Reboot when free with new incoming/outgoing call
barring. A reboot using the reset button is recorded in
the Audit Trail.
10 to 30.
Flashing orange Erase Configuration
Erase the configuration, alarm log and audit trail.
Immediate reboot without waiting for active calls to end.
See
Erasing the configuration
for full details.
30 to 40.
Red
Erase All.
Erase configuration, alarm log and core software. See
Erasing the Operational Software
for full details.
Over 40.
Flashing green
None
None.
8.14 AUX Button
IP500 V2 control units have an AUX button. This button can be used as follows.
·
If pressed during a restart of the control unit, the control unit
skips booting
from the /primary folder on the
System SD card.
·
If pressed for more than 5 seconds when a system is running, the control unit shuts down for 10 minutes.
152
183
124
Summary of Contents for IP500
Page 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Page 10: ......
Page 12: ......
Page 58: ......
Page 120: ......
Page 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 422: ......
Page 434: ......
Page 440: ......
Page 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...