8.3.1 Like for Like Replacement
If replacing with a component of the same type, no configuration changes are necessary.
To do a like for like replacement
1.
Shutdown the system
.
2. Switch off power to the system.
3. Remove the card or external expansion module. Note the card slot or expansion port used as the replacement must
be installed in the same position.
4. Install the replacement using the appropriate process for the type of component (
Fitting IP500 cards
,
Adding
External Expansion Modules
).
5. Restart the IP Office system.
8.3.2 Higher Capacity Replacement
If replacing with a component of the same type but higher capacity, when restarted the IP Office will automatically create
configuration entries for the new trunks or extensions/users.
To replace a component with one of the same type but higher capacity
1.
Shutdown the system
.
2. Switch off power to the system.
3. Remove the card or external expansion module. Note the card slot or expansion port used as the replacement must
be installed in the same position.
4. Install the replacement using the appropriate process for the type of component (
Fitting IP500 cards
,
Adding
External Expansion Modules
).
5. Restart the IP Office system.
6. Use IP Office Manager to configure the new trunks or extensions/users.
8.3.3 Lower Capacity Replacement
If replacing with a component of the same type but lower capacity, after restarting the IP Office the configuration will need
to be edited to remove redundant entries.
To replace a component with one of the same type but lower capacity
1.
Shutdown the system
.
2. Switch off power to the system.
3. Remove the card or external expansion module. Note the card slot or expansion port used as the replacement must
be installed in the same position.
4. Install the replacement using the appropriate process for the type of component (
Fitting IP500 cards
,
Adding
External Expansion Modules
).
5. Restart the IP Office system.
6. Use IP Office Manager to delete the trunks or extensions/users that are no longer supported by the component
installed.
8.3.4 Adding a New Component
If adding a new component to an available slot or port, when restarted the IP Office will automatically create configuration
entries for the new trunks or extensions/users.
To add a new component
1.
Shutdown the system
.
2. Switch off power to the system.
3. Install the replacement using the appropriate process for the type of component (
Fitting IP500 cards
,
Adding
External Expansion Modules
).
4. Restart the IP Office system.
5. Use IP Office Manager to configure the new trunks or extensions/users.
145
83
90
145
83
90
145
83
90
145
83
90
Summary of Contents for IP500
Page 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Page 10: ......
Page 12: ......
Page 58: ......
Page 120: ......
Page 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 422: ......
Page 434: ......
Page 440: ......
Page 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...