Installing IP500/IP500 V2
Page 357
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
System Components: Phone Add-Ons
10.12.2 4450
The maximum number of button module buttons supported, of any type, on a single system is
1024
.
The DSS4450 works in association with the 4412D and 4424D telephones, each of which can support up to two DSS4450
adjuncts.
Each DSS4450 provides an additional 60 programmable keys with single red lamps except for the bottom two rows which
have green lamps. The DSS4450 requires an auxiliary Avaya power supply unit and must be used with the cables supplied.
IP Office supports a maximum 2 x 4450 units on each Digital Station expansion module, including the IP406 V2 control
unit. A maximum of 8 x 4450 units total are supported on the whole IP Office system. For additional limitations see
Phone
Add-Ons
.
This phone is not supported on the IP500 DS8 Extension Card. For the IP500 it will work on external Digital Station
Expansion Modules.
4450
Feature
Detail
Connects via
DSS port on phone.
Supported by
4412D+, 4424D+
Maximum per phone
2.
Maximum per DS module/
control unit
2.
Maximum per IP Office
system
8.
Additional requirements
4450 power supply unit on phone.
IP Office Release
1.0+
Programmable Buttons
60
(50x
/10x
).
Item
SAP Code
4450 (Black)
108199696
4450 (White)
108199407
Small 4400 Series Stand (Black)
108541194
Small 4400 Series Stand (White)
108541202
Power Supply for 4450
108596412
355
355
Summary of Contents for IP500
Page 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Page 10: ......
Page 12: ......
Page 58: ......
Page 120: ......
Page 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 422: ......
Page 434: ......
Page 440: ......
Page 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...