33
Select the panel you want to connect to and click OK.
NOTE
Valid connections are shown in bold.
34
Select the method to use when connecting the panels and click OK.
then…
If you select…
the panel is added as a subfed panel to an existing
circuit in the linked panel.
Circuit breaker in panel
the panel is added as a subfed panel to a feed-thru
lug in the linked panel.
Feed-thru lugs
the panel will be added as a subfed panel to a subfeed
lug circuit in the linked panel.
Subfeed lugs
the panel will be added as a subfeed panel to a sub-
feed breaker circuit in the linked panel.
Subfeed breaker
the panel will be connected through a transformer
when panels are of different voltages.
Panels are connected through a transformer (panels
are different voltages)
NOTE
To remove the link to a panel, select the panel, click Panel tab
➤
Connections panel
➤
Remove
Connection To
.