Connection Details worksheet (showing details of a fitting)
The Connection Details worksheet displays the following information depending on the type of pipe object
that is selected. All values except location coordinates are read-only. You can edit Location X, Location Y,
and Elevation Y in this worksheet:
■
Nominal size: Size as specified in the routing preference
■
Flow direction: In, out, or bidirectional orientation of the flow of the pipe object
■
Connection type: Connection assignment that you make on the
on page 296
tab in the Pipe Layout Preferences dialog
■
Maximum tolerance angle (AoD): Maximum allowable angle of deflection for fittings stored in the catalog
content
■
Current tolerance angle: Current angle of deflection for the selected fitting as specified in the catalog
content
■
Location X, Location Y, and Elevation Z (editable): Applies to the 2D and elevation coordinates
TIP
Maximum tolerance angle (AoD) and current tolerance angle are displayed in current angle units.