Automatic Start
210E only. Panel will commence the start
sequence. Requires Automatic mode.
Automatic Stop
210E only. Panel will commence the stop
sequence. Requires Automatic mode.
Automatic Start/Stop
Panel will commence start when active, and
commence stop when inactive. Requires
Automatic mode.
Remote Start
210E only. Same as the local start button.
Disabled if panel in local mode.
Remote Stop
210E only. Same as the local stop button.
Disabled if panel in local mode.
Local Start
Local Start button
Local Stop
Local Stop button
Local Acknowledge
Used to acknowledge all events in the alarm list.
Local/Remote Acknowledge
Used to acknowledge all events in the alarm list
Remote Acknowledge
Used to acknowledge all events in the alarm list
Silence Buzzer
Silences the buzzer. Edge triggered.
Load Reduction Override
Puts the DCU in load reduction override mode.
Shutdown Override
210E only. Makes all the configured shutdown
channels into alarm channels, so engine will not
shut down automatically.
Engine overspeed shutdown is however always
enabled.
In Gear
210E only. From gearbox on prop. Engines.
Disables start attempts.
In Neutral
Neutral gear indication. Overrides any other In
Gear signal if configured.
In Gear (Ahead)
From gearbox on prop. Engines to indicate
Ahead gear.
In Gear (Astern)
From gearbox on prop. Engines to indicate
Astern gear.
Toggle Crank Mode
Toggle between crank modes.
Power On
Toggle Sleep mode.
Use As
configures the function used. Select
None
if the channel is to be used as an ordinary
switch input channel.
Input State
makes it possible to invert the behaviour of the function.
Page 20 (99)