Display Major Divider
selects the desired major divisions in the instrument, for US and Metric
values. The major divider number is displayed at each major divider.
Display Minor Divider
selects the desired minor divisions in the instrument, for US and Metric
values.
It is recommended to assign the major divider to a value which can be divided with
the total display range.
It is recommended to assign the minor divider to a value which can be divided with
the major divider.
Display Multiplier
selects the multiplication factor as necessary. An instrument with displayed
range 0-10,000 would display as 0-1,000 with a multiplication factor of 10. The multiplication
factor is displayed in the instrument (round gages only).
configures if any multiplier shall be used when presenting the channel.
Update Metric
and
Update US
can be used to copy and convert display configuration to
Metric or US units.
When using Update Metric or Update US, the application does not round off
values. It is highly recommended to adjust the calculated values by hand, and set
sensible round figure values.
Mirrored View
configures the gauges to have the minimum display range set to the
maximum together with a colored indication. This is typically used for rudder angle display.
Normal View
Mirrored View
Alarming
Settings for how the events are configured for the channel. This section is always completed
in the currently selected system unit. To switch units, simply change units units using the
DCU panel..