home / dcu / i/o configuration / engine load
In order to configure engine load, the DCU requires to have at least one analog channel
(4-20 mA, 0-5 V input or J1939) with a Sensor Unit of Percent. For electronic engines this
can typically be J1939 PGN 0XF003, SPN 92.
The engine load selected is now used as engine load when configuring alarms.
4.3.4 Transmission
The transmission section is used to configure transmission related channels. They are used
for Gear Control and visualization. For information on how to enable Gear Control, see the
User Interface chapter.
home / dcu / i/o configuration / transmission
4.3.4.1 Gear
Gear is used as a start interlock, and can also be configured as an additional setting for
alarms. Gear can also be configured to be shown in the header, as well as in pages.
Page 29 (99)