● Certified by major classification societies (DCU 410E/408E only)
9.1.2 Total I/O capacity
The I/O capacity of the DCU can be expanded using one or more of the RIO units.
Signal type
DCU 400E DCU 200E RIO 410 RIO 210 RIO 412 MK-14
4-20 mA
4
19
9
-
-
-
PT100
4
2
8
8
-
-
Switch Inputs
8
21
4
6
-
-
Thermocouple K-type
0
0
2
2
20
-
Configurable Relays
2
2
2
2
-
14
Configurable 24V Out
4
19
2
2
-
-
0-5V Inputs
0
19
1
8
-
-
J1939 Channels
Many
Many
-
-
-
-
RIO 410 Support
4
1
RIO 210 Support
1
1
RIO 412 Support
1
1
MK-14 Support
1
-
Note that the standard I/O capacity of the DCU210E/208E utilizes flexible I/O,
meaning a total of 19 I/O are available for 4-20mA, Switch Input, 24V output, and
voltage input. If the secondary J1939 interface is not used, additional 2 switch
inputs can be used.
10 RIO 410 Configuration
The configuration of the RIO 410 is part of the DCU configuration. From the DCU web server
home page, select RIO.
Page 89 (99)