home / dcu / miscellaneous / sea trial / configure signal
list
This section is used to define a list of sensor data that is to be sampled during a sea trial run.
Signals
Displays the currently configured list of signals.
Append Signal
By selecting a signal from the combo box and clicking Submit, the chosen signal is added to
the list. Any signal currently enabled (including signals configured as Seatrial Only can be
added to the list. It is only possible to add a signal once, so only signals currently not on the
list are available.
List Presets
Provides a few predefined list options. If selecting any of these options and pressing submit,
the current list is replaced by a preset list of signals.
8.10.3 Inspect Signals
home / dcu / miscellaneous / sea trial / inspect signals
Provide a quick view of the status of the current list of sea trial signals. Each signal is
displayed together with its current value if available. Reload the page to get a new reading of
signal values.
8.10.4 Sample
home / dcu / miscellaneous / sea trial / sample
Can be used to sea trial to retrieve a sample of all configured signals. If a USB stick is
inserted in the DCU the sample is also stored on the USB drive.
Page 87 (99)