home / dcu / user interface / controls
Aftertreatment
Aftertreatment system control, SPN 8148, and operating mode, SPN 9175, can be controlled
by DCU if configured.
Enable Aftertreatment System Control
enables the transmission of SPN 8148. If enabled the
operator can toggle this in the DCU interface, under Controls. If
Aftertreatment System
Control in Local Mode
is configured to any switch channel, this will override the current
setting making aftertreatment system control available by switch channel only.
Aftertreatment System Control Emergency Off
can be configured to any enabled switch
channel to work as an emergency off for the aftertreatment system, effectively transmitting
Off in SPN 8148.
Enable Aftertreatment Operating Mode Control
enables the transmission of SPN 9175. If
enabled the operator can toggle the mode (Standard / Reduced) in the DCU interface, under
Controls. If
Local Mode Control of Aftertreatment Operating Mode Control
is configured to
any switch channel, this will override the current setting making mode control available by
switch channel only.
Gear
Enable Gear Control
enables gear control and will show a Gear Control Form in the DCU.
Page 60 (99)