![Amada MM-L300A Original Instructions Manual Download Page 77](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797077.webp)
MM-L300A
6. How to Operate the PC Software
6-36
Calculate mode: Range
Since the upper limit judgment value is the maximum value of the selected data and
the lower limit judgment value is the minimum value of the selected data, upper limit
and lower limit are calculated in the set section respectively.
Example: The integrated value of upper limit (yellow shaded area) in the section
between 0.1002 s and 0.501 s is 78,617,240, and the integrated value of lower limit
(green shaded area) is 23,985,779.
Calculate mode: 3
σ
Since the upper limit judgment value is the +3
σ
value of the selected data and the
lower limit judgment value is the -3
σ
value of the selected data, upper limit and lower
limit are calculated in the set section respectively.
Example: The integrated value of upper limit (yellow shaded area) in the section
between 0.1002 s and 0.501 s is 78,642,000, and the integrated value of lower limit
(green shaded area) is 0.
Lower limit
judgment value
Upper limit
judgment value
Summary of Contents for MM-L300A
Page 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Page 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Page 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Page 180: ......