MM-L300A
9. Interface
9-15
(5) When conditions are switched by external I/O in internal trigger mode and remote
mode
Conditions are switched by external I/O before laser processing and condition
number is changed in the order of 0
→
3
→
15
→
63.
The following diagram shows the lapse of time in the case where measurement by
laser processing is performed 3 times, all 3 times are judged as OK, and pulse
output is made.
(*: Operation on the user side)
Condition 0 input *
Condition 1 input *
Within 3ms *6
Condition 2 input *
*5
Condition 3 input *
Condition 4 input *
Condition 5 input *
Meas. condition No.
0
3 *6
Laser processing *
Internal trigger
*3
MM-L300A
measurement
the set condition
MEASURE output
the set condition
Monitor OK output
(pulse output)
Depending on
*4
5.5ms or more *7
*4
63
250μs×Setting times (100 max.) *1
Depending on
15
500μs max.
450μs max.
*5: The measurement condition switching can be changed even while the
MM-L300A
performs measurement if it is later than the MEASURE output.
*6: When the interval between Condition 0 and Condition 1 is later than 3 ms,
condition number is transmitted to the
MM-L300A
in the order of 0
→
1
→
3.
To turn on and off multiple conditions, change all conditions within 3 ms after the
condition switching start.
*7: The measurement condition switching is changed 5.5 ms after the condition
switching start.