![Amada MM-L300A Original Instructions Manual Download Page 132](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797132.webp)
MM-L300A
9. Interface
9-6
(7) MEASURE
This is an interface connector with the external control device.
Pin No.
Description
1
0-5V OUT (ANALOG OUT+ (out))
The value which an incident light is converted into voltage is output.
2
Analog GND (ANALOG OUT- (out))
When measuring pin No.1, connect to the GND on the measuring side.
3 Unused
Do not connect anything.
4
0-10V input (TRR(in))
When 10 V is input, a measurement of the
MM-L300A
can be started at an
arbitrary timing.
5
Analog GND (TRRIGER_IN-(in))
When inputting voltage to pin No.4, connect to the GND on the measuring side.
6 Unused
Do not connect anything.
7
Measuring signal (MEASURE OUT+ (out))
When the
MM-L300A
is measuring waveforms, the circuit between MEASURE
OUTs is closed internally.
This is the same signal as pin No. 5 (MEASURE OUT+) of the TRIGGER connector
on the
MM-L300A
.
8
Measuring signal (MEASURE OUT- (out))
When the
MM-L300A
is measuring waveforms, the circuit between MEASURE
OUTs is closed internally.
This is the same signal as pin No. 6 (MEASURE OUT-) of the TRIGGER connector
on the
MM-L300A
.
9 Unused
Do not connect anything.
10 Unused
Do not connect anything.
MEASURE
8 1
7 2
6 3
5 4
9 10