![Amada MM-L300A Original Instructions Manual Download Page 119](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797119.webp)
MM-L300A
7. Basic Operation
7-11
2) Click the [Start data receive] button on the Acquire Wave Data Window.
When measurement waveforms are saved in the memory of the
MM-L300A
,
they are transferred to the personal computer. (Refer to
6. (4) Acquire Wave
Data Window
.)
3) Emit a laser with a data receiving state and perform measurement with the
MM-L300A
.
Since it is desirable that the waveform intensity is near the maximum value
(around 50,000 is recommended), when the waveform cannot be obtained or
the maximum value is significantly lower than 50,000, perform setting of the
MM-L300A
again referring to
12. (1) Troubleshooting
.
After obtaining data, click the [Stop data receive] button to finish the
measurement of the
MM-L300A
.
Click the [Menu] button to return to the Menu Window.