![Amada MM-L300A Original Instructions Manual Download Page 121](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797121.webp)
MM-L300A
7. Basic Operation
7-13
2) Obtain sample waveforms several times with the same processing conditions
of a good product as Step 1 and setting conditions of the
MM-L300A
.
The larger the number of sample waveforms is, the more stable data is.
(Example) Measuring waveforms with processing conditions of a good product 10
times
3) Return to the Menu Window and select the condition number set when the
sample waveform is obtained to display the Condition Configuration Window.
(Refer to
7. (1) Setting Conditions
.)
4) Click the [Waveform Calculation] button and select all sample waveforms of
multiple times obtained in Step 2.
After selection, clicking the [Calculate] button displays the reference
waveform of the selected sample waveform and at the same time returns to
the Acquire Wave Data Window.
When the measurement waveform is not displayed, click the [Filter] button to
check that the condition is proper. (Refer to
6. (7)
Filter
.)