MM-L300A
6. How to Operate the PC Software
6-21
(1) Waveform graph viewer
When the [Graph] button on the Basis Waveform Calculation Window is clicked, the
graph of the waveform data selected in the waveform data list is displayed. Up to 100
waveform data can be displayed.
The graph is enlarged or reduced by turning a mouse wheel up and down (up:
enlarged, down: reduced).
Also, putting a mouse pointer on the displayed waveform displays date and time in the
selected information so that you can check which waveform information is displayed.
When [NG Point View] is selected, the graph above the range of [Upper Limit] or below
the range of [Lower Limit] is displayed in NG (color selected in [NG Line] of [Line Color]
on the Maintenance Window. [RED] in the example below).