![Amada MM-L300A Original Instructions Manual Download Page 49](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797049.webp)
MM-L300A
6. How to Operate the PC Software
6-8
(3) Menu Window
When the application starts, this window is first displayed.
On this window, you can select to move to the Acquire Wave Data Window, the
Condition Select Window, or the Maintenance Window.
No. Item
Description
(1)
Status display
The connection state with the
MM-L300A
is displayed.
Online: Indicates that connection between this application and
the
MM-L300A
is established.
Offline: Indicates that this application and the
MM-L300A
are
not connected.
(2) Condition
Number
The condition number (00 to 63) set on the
MM-L300A
is
displayed. The condition number can be set in either [Local
mode] or [Remote mode].
During editing, the number is displayed in red. When determined
by [Enter], it changes to black.
The
MM-L300A
starts in [Remote mode] when turned on. Also,
even if [Local mode] is selected, the mode is changed to
[Remote mode] when this application is shut down.
At the time of off-line, [Local mode] / [Remote mode] is not
displayed.
Local mode: Sets via this application.
Remote mode: Sets via EXT. I/O.
(3)
Unit ID
The unit ID number set in the connected
MM-L300A
is
displayed. It can be changed on the Maintenance Window.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)