![Amada MM-L300A Original Instructions Manual Download Page 166](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797166.webp)
MM-L300A
12. Maintenance
12-11
4) Slide the sheet metal cover from the front side to the rear side and pull it
upward to remove it.
5) Replace an old battery with a new one not to touch the power supply part.
6) Insert the cover from the rear side and mount it by sliding the front side.
7) Tighten four screws with 0.63 N
・
m of general torque.
8) Turn the power on.
9) Start the equipment and confirm that the battery error disappears.
10) Perform the Set Current Time. (Refer to
6. (10) Maintenance Window
.)
Front side
Slide
Battery
Powe
r su
ppl
y p
art
Pull up
Rear side
Front side
Rear side
Wear gloves