![Amada MM-L300A Original Instructions Manual Download Page 71](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797071.webp)
MM-L300A
6. How to Operate the PC Software
6-30
3) Set the upper/lower limit judgment value, and then set the position from
Average, Range, or ±3
σ
in the unit of %. (1%
≒
graph intensity scale ×
1/100)
If the setting range conditions above is not satisfied, a message appears when a
condition is changed or added.
Click the [OK] button to return.
4) Click the [Set Condition] button to determine the setting.
Also, when the [Set Condition] button is clicked, the Detail Condition Window is
displayed and setting contents can be checked. The Detail Condition Window can also
be displayed by clicking the [Detail Display] button.
Upper/lower limit
judgment
value of this section is
changed to specified value.