MM-L300A
6. How to Operate the PC Software
6-34
(8) Integral Configuration Window
Click the [Integral] button on the Condition Configuration Window to display the Integral
Configuration Window, and set conditions of integral judgment.
This function will be effective when the amplitude is large and it is difficult to perform a
judgment only with the upper/lower limit judgment value.
No. Item
Description
(1)
Section data list
The setting contents (start/end point, upper/lower limit setting
value) of each setting section are displayed. Click the row of the
section to set with a mouse to switch the setting section.
(2) Setting
section
display
The currently effective setting section is displayed.
(3)
Calculate mode
Selects the upper/lower limit judgment value to display in the
waveform display from Average, Range, and 3
σ
. The default is
[Average].
(4)
Upper
On the left side, the integrated value of the upper limit judgment
value of the mode selected for [Calculate mode] is displayed.
When inputting a ratio of the setting value to the integrated value
of the upper limit judgment value (0 to 999%), the judgment value
is displayed on the right side.
The judgment value can be input directly. When inputting
directly, “---” is displayed in the column of ratio.
When the [Set] button is clicked, the upper limit of the setting
section in the section data list changes to the contents edited.
(10)
(1)
(6)
(7)
(2)
(9)
(4)
(5)
(3)
(8)
Summary of Contents for MM-L300A
Page 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Page 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Page 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Page 180: ......