![Amada MM-L300A Original Instructions Manual Download Page 169](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797169.webp)
MM-L300A
13. Specifications
13-1
13. Specifications
MM-L300A
Dimensions
230 (W) x 243 (D) x 89 (H) mm (excluding connector)
230 (W) x 391 (D) x 129 (H) mm (when connecting external
trigger unit)
Input supply voltage
Single-phase 90 - 250 V AC, 50/60 Hz
Power consumption
18 W or less
External control interface
Input/output: 15-pin, D-Sub (female)
Input channel
1 channel
Minimum measuring time resolution
1
μ
s
Measuring time setting range
1
μ
s to 999 sec
Judging function
Envelope (upper/lower limit setting)
Maximum storage number of waveform
data
20000
Ambient operating temperature
0 to 40ºC (without condensation)
Ambient operating humidity
85%RH or less (without condensation)
Mass
Approx. 3.0 kg
Grounding class
Class D grounding
External network
Optionally available (Refer to
11. EtherNet/IP
.)
Ex
te
rna
l trigge
r unit
*1
(opti
on)
Dimensions
230 (W) x 391 (D) x 49 (H) mm
Supply power voltage
Supplied from the
MM-L300A
main unit
Detection wavelength
900 to 1,700 nm
Ambient operating temperature
0 to 40ºC (without condensation)
Ambient operating humidity
85%RH or less (without condensation)
Mass Approx.1.4
kg
SU-N300A
Dimensions
50 (W) x 35 (D) x 96 (H) mm (excluding connector)
50 (W) x 35 (D) x 106 (H) mm (when filter equipped, excluding
connector)
Measuring spot diameter
Approx.
φ
2 mm when W.D. is 200 mm
Sight
Green LED (
λ
= approx. 525 nm)
Detection wavelength
1,300 to 2,500 nm
Ambient operating temperature
*2
5 to 50ºC (without condensation)
Ambient operating humidity
85%RH or less (without condensation)
Protection class
IP64 (when connector and cable connected)
Mass
Approx. 0.2 kg
Cooling method
Air-cooled
*3