![Amada MM-L300A Original Instructions Manual Download Page 145](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797145.webp)
MM-L300A
10. JSON
10-3
“data-points” : 3000,
“skip-times” : 0,
“average-times” : 1,
“sampling” : 1,
“date” : 1498529161000000,
“integration” : 805228545,
“min” : 0,
“max” : 65535,
“condition” : 63,
“wave-data” : [65535, 65535, ………, 65535]
“
Integral-num” : 3,
“
Integral-judge” : [0, 1, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0],
“
Integral-data” : [12345, 23153, 0]
}
(3) Returning the total number of waveforms obtained from the start of the
MM-L300A
Input and send GET:http://___.___._.__/api/1/waves/total.json.
This value is not reset by [Counter Reset] on the PC software.
Name Data
type
Note
total-count
Number
Total number of waveforms from the start of the
MM-L300A
(0 to 18446744073709551615)
Sample layout of JSON object
{“total-count” : 20000 }
Number of valid data (data-points), m
Number of partial integration (Integral-num), l
(IP address of MM-L300A)