(12) Setting Parameters List
Shown below is parameters list set on each window.
Menu Window
Item Contents
Range
(default)
Condition Number
Specifies the condition number.
00 to 63 (00)
Acquire Wave Data Window
Item Contents
Range
(default)
- -
-
Condition Select Window
Item Contents
Range
(default)
Unit ID
Specifies the ID of the
MM-L300A
.
(can be set at the time of off-line.)
00001 to 65535
(ID specified on the
Maintenance Window)
Condition Configuration Window
Item Contents
Range
(default)
Measurement Time
Specifies the time required for obtaining a
waveform.
1 to 999 (300)
Specifies the unit of the time required for
obtaining a waveform.
usec, msec, sec (msec)
*1
Comment
Specifies the name of condition.
-
Upper Limit
Specifies the upper limit of judgment.
-100 to 100 (50)
*2
Lower Limit
Specifies the lower limit of judgment.
-100 to 100 (-50)
*2
Threshold
Specifies the judgment threshold.
0 to 65535 (0)
Edit Start Point
Specifies the start point of judgment.
0 to 999
Edit End Point
Specifies the end point of judgment.
0 to 999
*1 Up to 999 sec.
*2 Default value in an unregistered state. Default in calculation is (0).
Basis Waveform Calculation Window
Item Contents
Range
(default)
Waveform selection
menu
Selects / selects all / deselects all
measurement waveform(s).
Select, Select All
*1
,
Deselect All (Deselect All)
Waveform display
The selected waveform is displayed by the
[Graph] button.
1 to 100
*2
(0)
Display start number
Specifies the start number to display the
measurement waveform.
1 to the number found by
filtering conditional search
*1
(1)
*1 The maximum number of measurement waveforms is 65535.
*2 The maximum number of waveforms to be graphically displayed is up to 100. Also,
in [Select All], waveform of a page displayed is displayed by switching the page.