![Amada MM-L300A Original Instructions Manual Download Page 149](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797149.webp)
MM-L300A
11. EtherNet/IP
11-4
MM-L300A
setting
The default TCP/IP setting of the ANYBUS connector of the
MM-L300A
is DHCP
(Dynamic Host Configuration Protocol). Automatically obtained from the DHCP
server.
The DHCP setting can be disabled. The
MM-L300A
uses Anybus CompactCom 40
EtherNet/IP of HMS Industrial Network AB. Using Anybus IPconfig which can be
downloaded free of charge from HMS’s website
www.anybus.com
, the network setting
such as IP address and validity/invalidity of DHCP can be changed.
The network setting can also be obtained through the TCP/IP interface object.
Preparation of scanner (client) device
To make the
MM-L300A
participate in network, you need to first install the device
profile (EDS (Electronic Data Sheet) file) of the
MM-L300A
to a scanner (client)
device. A scanner (client) device communicates with the
MM-L300A
based on the
EDS file.
Install the attached EDS file to a scanner (client) device. For how to install, refer to the
operation manual for a scanner (client) device.
How to get the EDS file
[MM-L300A_V1_1.eds] in the CD of the attached MM-L300A application software
(AS1193660) is the EDS file of EtherNet/IP.