MM-L300A
11. EtherNet/IP
11-7
#
Data name
Data type
Access
Data contents
17 Use memory Area
UINT
Get
Used memory area
18 Current Time
USINT array [5]
Get
Current time
[0]: Year (last two digits)
[1]: Month
[2]: Day
[3]: Hour
[4]: Minute
[5]: Second
19 Digital Gain
UINT
Get/Set
Digital gain
Decimal-point omitted value (1.0000 setting
of the PC software is 10000.)
20 Digital
Offset
INT
Get/Set
Offset
21 Trigger Value
UINT
Get/Set
Trigger setting
22 DO
Output
Type
BYTE
Get/Set
Output setting of EXT. I/O (0 = Level, 1 =
Pulse output)
Each bit shows the following output setting.
bit0: READY (Pin 11)
bit1: ERROR (Pin 12)
bit2: OK (Pin 13)
bit3: NG (Pin 14)
bit4 to bit7: (Reserve)
23 Guide
BOOL
Get/Set
ON/OFF of guide light
0 = Guide light OFF
1 = Guide light ON