13. Specifications
13-2
SG-N300A
Dimensions of sensor part
50 (W) × 261 (D) × 50 (H) mm (excluding connector)
101.5 (W) × 345 (D) × 50 (H) mm (when connecting external
trigger input unit)
Dimensions of light-receiving part
55 (W) × 35 (D) × 44 (H) mm (excluding sensor fiber)
Mounting method
Fixed (installation to excluding robot or moving stage)
Measuring spot diameter
Refer to outline drawings.
Laser welding layout condition
Use conditions avoiding damage risk by reflected light
*4
Sensor fiber allowable bending radius
Short: R30 mm
Long: R60 mm
Sight Not
equipped
Detection wavelength
1,300 to 2,500 nm
Ambient operating temperature
*2
*5
5 to 50ºC (without condensation)
Ambient operating humidity
85%RH or less (without condensation)
Recommended ambient temperature
5 to 35ºC (without condensation)
Protection class
IP64 (when connector and cable connected)
Mass
Approx. 1.0 kg
Approx. 1.3 kg (when assembling external trigger input unit)
Cooling method
Air-cooled
*3
Common
Vibration when in use
Continuous vibration test (test level: Class S)
Frequency: 5 to 14 Hz amplitude control (1.25 mmp-p)
14 to 100 Hz acceleration control (0.5 G) or less
Short-duration vibration test (test level: Class S)
Frequency: 1 to 7 Hz amplitude control (10 mmp-p)
7 to 100 Hz acceleration control (1.0 G) or less
Dust, oil mist
JEITA Class S: 8 mg/m
3
or less, 0.1 mg/m
3
or less
Temperature during transport or storage -10 to 60ºC (without condensation)
Humidity during transport or storage
85%RH or less
Vibration during transport
ASTM D 4728 Level2
Impact during transport
ASTM D 4169-05 Level2
Overvoltage category
II, only use of an outlet
Altitude
2000 m max.
CE marking
MM-L300A
and
SU-N300A
are applicable.
*1: Use this product in the environment without conductive dust. If conductive dust enters in the
product, this may result in a failure, electric shock, or fire. When using this product in this
environment, make contact with us.
*2: It is recommended to use in the environment where the temperature change is small.
*3: When the
SU-N300A
stores heat by diffusion reflected light from workpiece, you need to take
cooling measures such as water-cooled jacket or measures against reflected light. For details, refer
to
5. (5)
to
(7)
.
*4: The laser reflected light may cause damage by heat storage or burning of parts. For details, refer to
5. (8) Measures against Reflected Light to the SG-N300A
.
*5: Environmental temperature dependency:
This device has environmental temperature dependency and the offset value (measured value
when light is not received) changes depending on environmental temperature. The variation
quantity depends on the setting value of the analog gain as shown in the graph below. To reduce