9. External Communication Function
9-23
11) Specified code No.: S11 (Monitor value output)
Used when SCHEDULE MODE on the STATUS screen is SINGLE.
In case of DOUBLE, use Specified code No. S12.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S11[CR][LF]
MD series -> Host PC
!01008S11: 001212, kA, 2.00, 1.86, 3.20, 2.61, 04.9, 1.40, 1.00, 1.43, 0.75, 1.00
A B
C D
E F
G H
I J K L
[CR][LF]
Item
Character
string
Content Range
A
******,
Counter
000000 to 999999
B **,
Unit of current value
_A: Current value in A
(
_
indicates space)
kA: Current value in kA
A or kA
C
****,
*1
WELD: Current peak value
0000 to 0999[A] ,----
*5
*.**,
*2
0.00 to 9.99[kA] ,----
*5
D
*.**,
*1
WELD: Current average value
0000 to 0999[A] ,----
*5
**.*,
*2
0.00 to 9.99[kA] ,----
*5
E
*.**,
WELD: Voltage peak value
0.00 to 9.99[V] ,----
*5
F
*.**,
WELD: Voltage average value
0.00 to 9.99[V] ,----
*5
G
*.**,
*1
WELD: Power average value
0.00 to 9.99[kW] ,----
*5
**.*,
*2
00.0 to 99.9[kW] ,----
*5
H
*.**,
WELD: Resistance average value
0.00 to 9.99[m
Ω
] ,----
*5
I
*.**,
*4
WELD: Weld time
(Set time)
0.00 to 9.99[ms]
**.*,
*5
00.0 to 99.9[ms]
J
****,
*1
PRECHECK: Current peak value
0000 to 0999[A] ,----
*5
*.**,
*2
0.00 to 9.99[kA] ,----
*5
K
*.**,
*1
PRECHECK: Current average value
0000 to 0999[A] ,----
*5
**.*,
*2
0.00 to 9.99[kA] ,----
*5
L
*.**
*3
PRECHECK: Weld time
(Set time)
0.00 to 1.00[ms]
**.*
*4
00.0 to 01.0[ms]
*1: When CURRENT RANGE on the STATUS screen is ***A.
*2: When CURRENT RANGE on the STATUS screen is *.**kA.
*3: When WELD TIME on the STATUS screen is NORMAL.
*4: When WELD TIME on the STATUS screen is LONG.
*5: When the value exceeds the display range.