9. External Communication Function
9-17
6) Specified code No.: S05 (COMPARATOR screen)
Used when SCHEDULE MODE on the STATUS screen is DOUBLE.
In case of SINGLE, use Specified code No. S04.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S05[CR][LF]
MD series -> Host PC
!01008S05: kA, 2.20, 1.80, 3.20, 2.80, 0, 1.20, 0.80, 1.70, 1.30, 0,
A B C D E F
G H I J
K
02.2, 01.8, 04.7, 04.3 [CR][LF]
L M
N O
Item
Character
string
Content Range
Increment/
Decrement
A **,
Unit of current value
_A: Current value in A
(
_
indicates space)
kA: Current value in kA
A or kA
-
B
****,
*1
W1: Weld 1 current upper limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
C
****,
*1
W1: Weld 1 current lower limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
D
****,
*1
W2: Weld 2 current upper limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
E
****,
*1
W2: Weld 2 current lower limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
F *,
Current judgment setting
0: With average value
1: With peak value
0 to 1
1
G
*.**,
W1: Weld 1 voltage upper limit
0.00 to 9.99[V]
0.01
H
*.**,
W1: Weld 1 voltage lower limit
0.00 to 9.99[V]
0.01
I
*.**,
W2: Weld 2 voltage upper limit
0.00 to 9.99[V]
0.01
J
*.**,
W2: Weld 2 voltage lower limit
0.00 to 9.99[V]
0.01
K *,
Voltage judgment setting
0: With average value
1: With peak value
0 to 1
1
L
*.**,
*1
W1: Weld 1 power upper limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
M
*.**,
*1
W1: Weld 1 power lower limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
N
*.**,
*1
W2: Weld 2 power upper limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
O
*.**,
*1
W2: Weld 2 power lower limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
*1: When CURRENT RANGE on the STATUS screen is ***A.