MD Series
6. Explanation of the Screen
6-7
(b) CURR
Set the upper limit (H) and the lower limit (L) of current for WE1 and WE2
respectively.
The setting range is 0.00 kA to 9.99 kA or 000 A to 999 A.
You can select either AVE (average value) or PEAK (peak value) for
upper/lower limit judgment.
When SCHEDULE MODE on the STATUS screen is set to SINGLE, upper
limit (H), lower limit (L) and measured value of WE2 are not displayed.
(c) VOLT
Set the upper limit (H) and the lower limit (L) of voltage for WE1 and WE2
respectively.
The setting range is 0.00 V to 9.99 V.
You can select either AVE (average value) or PEAK (peak value) for
upper/lower limit judgment.
When SCHEDULE MODE on the STATUS screen is set to SINGLE, upper
limit (H), lower limit (L) and measured value of WE2 are not displayed.
(d) POWER
Set the upper limit (H) and the lower limit (L) of power for WE1 and WE2
respectively.
The setting range is 00.0 kW to 99.9 kW or 0.00 kW to 9.99 kW.
When SCHEDULE MODE on the STATUS screen is set to SINGLE, upper
limit (H), lower limit (L) and measured value of WE2 are not displayed.
(e) Measured value
Displays the measured value of previous welding.
When SCHEDULE MODE on the STATUS screen is set to SINGLE, upper
limit (H), lower limit (L) and measured value of WE2 are not displayed.
When the measured value exceeds the display range, --- is displayed.
Note) Waveform and measured value hold the latest data of each schedule.
When the power is turned off, all values are cleared.