MD Series
7. Basic Operation
7-2
→
Enter [OFF] to change the schedule.
→
Set the output type of trouble signal to NC.
→
Set the detection start time of no current/no voltage to 0.5 ms.
→
Set the measurement start time to OFF.
→
Set the length of weld time to NORMAL.
→
Selects the operation mode of the start input.
To start the weld sequence with the 2nd.STAGE terminal,
set START SIG. INPUT to 2ND.
To start the weld sequence with the combination of the
1st.STAGE and the 2nd.STAGE terminals, set START
SIG. INPUT to 1ST+2ND.
⑥
Move the cursor to COMM and press the ENTER key to go to the following screen.
To perform communication, set items referring
to
6. (6)
○
21
COMMUNICATION CONTROL
to
○
24
COMMUNICATION SPEED
.
In this example, set as shown at left not to
perform communication.
Move the cursor to BACK and press the
ENTER key to move to the second screen of
the STATUS screen.
⑦
Move the cursor to ERROR and press the ENTER key to go to the following screen.
Set the signals (trouble/caution signals) to be
output when a fault occurs.
In this example, all items are set OFF to output
the trouble signal.
ON: Caution signal output; start signal acceptable
OFF: Trouble signal output; start signal unacceptable
Operation on the STATUS screen is now complete.
Press the MENU key to return to the menu screen.