MD Series
9. External Communication Function
9-19
8) Specified code No.: S07 (STATUS screen)
Data strings: When reading Device No. 01 (Set 000 for Schedule No.)
Host PC -> MD series
#01R000S07[CR][LF]
MD series -> Host PC
!01000S07: 00, 3, 1, 0, 3, 2, 0, 1, 1, 0, 0, 4, 00.5, -00.1, 0, 0, 0, 0 [CR][LF]
A B C D E F
G H I J K L M N O P Q R
Item
Character
string
Content Range
Increment/
Decrement
A **,
CHARGE VOLTAGE:
Charge voltage
00: AUTO
07: 18V
01: 6V
08: 20V
02: 8V
09: 22V
03: 10V
10: 24V
04: 12V
11: 26V
05: 14V
12: 28V
06: 16V
13: 30V
00 to 13
-
B *,
CURRENT RANGE:
MD-A8000B
0: 999A
1: 2.00kA
2: 4.00kA
3: 9.99kA
MD-B4000B
0: 500A
1: 999A
2: 2.00kA
3: 5.00kA
0 to 3
1
C *,
SCHEDULE MODE:
Number of steps
0: SINGLE
1: DOUBLE
0 to 1
1
D *,
CONTROL:
Welding control method
0: CURR
1: VOLT
2: COMB.
0 to 2
1
E *,
START SIG.TIME:
Start delay time
0: 1ms
1: 5ms
2: 10ms
3: 20ms
0 to 3
1
F *,
START SIG.HOLD:
Start self-holding
0: NO HOLD
1: WE HOLD
2: SQ HOLD
0 to 2
1
G *,
SCHEDULE#:
Schedule selection method
0: EXT.(P)
1: EXT.(NP)
2: PANEL
0 to 2
1
Summary of Contents for MD-A8000B-05 Series