Data code table
1) Specified code No. table
Specified
code No.
Content
S01
SCHEDULE screen setting (Only when SCHEDULE MODE on the STATUS
screen is SINGLE)
Changes the conditions of weld sequence.
Specify Schedule No. and Specified code No. to perform reading and writing.
S02
SCHEDULE screen setting (Only when SCHEDULE MODE on the STATUS
screen is DOUBLE)
Changes the conditions of weld sequence.
Specify the schedule No. and specified code No. to perform reading and writing.
S03
MONITOR screen setting
Changes the items displayed on the MONITOR screen.
Specify the specified code No. to perform reading and writing.
Set 000 for Schedule No.
S04
COMPARATOR screen setting (Only when SCHEDULE MODE on the STATUS
screen is SINGLE)
Changes the upper/lower limit of monitor value.
Specify the schedule No. and specified code No. to perform reading and writing.
S05
COMPARATOR screen setting (Only when SCHEDULE MODE on the STATUS
screen is DOUBLE)
Changes the upper/lower limit of monitor value.
Specify the schedule No. and specified code No. to perform reading and writing.
S06
PRECHECK screen setting
Changes the conditions of precheck welding.
Specify the schedule No. and specified code No. to perform reading and writing.
S07
STATUS screen setting
Changes the initial setting.
Specify the specified code No. to perform reading and writing.
Set 000 for Schedule No.
S08
COMMUNICATION SETTING screen setting
Changes the communication setting.
Specify the specified code No. to perform reading and writing.
Set 000 for Schedule No.
S09
ERROR SETTING screen setting
Selects the signal output when a fault occur from fault and caution.
Specify the specified code No. to perform reading and writing.
Set 000 for Schedule No.
S11
(Read only)
Monitor value output (Only when SCHEDULE MODE on the STATUS screen is
SINGLE)
Outputs the last monitor value of each schedule No.
Specify the schedule No. and specified code No. to perform reading.
S12
(Read only)
Monitor value output (Only when SCHEDULE MODE on the STATUS screen is
DOUBLE)
Outputs the last monitor value of each schedule No.
Specify the schedule No. and specified code No. to perform reading.
S13
Output and resetting of fault item
Outputs and resets the occurring fault code
Specify the specified code No. to perform reading and writing.
Set 000 for Schedule No.