MD Series
6. Explanation of the Screen
6-3
(b) TIME
Time period of each movement in welding is set at the dimension of ms.
Refer to
5. (4) Timing Chart
on the relation of each period.
SQ
Time required until appropriate force is applied to the
workpiece.
WE1
Time during which WE1 welding current is applied.
COOL
Time during which welding current is stopped and the
workpiece is cooled.
WE2
Time during which WE2 welding current is applied.
HOLD
Time during which the workpiece is held after the welding
current has been applied.
↗
(*1)
Upslope (gradual increase in welding current) time.
Set it for WE1 and WE2 respectively.
↘
(*1)
Downslope (gradual decrease in welding current) time.
Set it for WE1 and WE2 respectively.
*1: When the welding portion except upslope and downslope is short
(there is not so much of a difference between the weld time (WE1
and WE2) and the time of [u downslope]), the set current
value and the monitored average value may be different. The
difference between the set value and the monitored value varies
depending on the rise rate of current.
The monitored interval can be set in MONITOR FIRST TIME. (Refer
to
(6)
⑮
MONITOR FIRST TIME
.)
(c) CURR
Control current value. WE1 and WE2 are set, respectively.
When CONTROL on the STATUS screen is set to CURR, VOLT is not
displayed.
Also, CONTROL is set to VOLT, CURR is not displayed.
(d) VOLT
Control voltage value. WE1 and WE2 are set, respectively.
When CONTROL on the STATUS screen is set to CURR, VOLT is not
displayed.
Also, CONTROL is set to VOLT, CURR is not displayed.