MD Series
4. Name and Functions of Each Section
4-5
Terminal
No.
Description
5
[2nd.STAGE] terminal
2nd.STAGE start input terminal.
Set START SIG. INPUT on the STATUS screen before using this terminal.
(Refer
to
6.(6)
⑰
START SIG. INPUT
.)
To start the weld sequence with the [2nd.STAGE] terminal, set START SIG.
INPUT to 2ND.
To start the weld sequence with the combination of the [1st.STAGE] and the
[2nd.STAGE] terminals, set START SIG. INPUT to 1ST+2ND.
[When START SIG. INPUT is 1ST+2ND]
When the [2nd.STAGE] terminals is closed with [1st.STAGE] terminal closed,
the weld sequence is started in the usual manner.
When the [1st.STAGE] terminal is open, the weld sequence does not start
even if the [2nd.STAGE] terminal is closed.
[When START SIG. INPUT is 2ND]
When the [2nd.STAGE] terminal is closed,
24 V DC is output from the [SOL]
terminal of Terminals 33 and 34, the weld force is applied, and the weld
sequence starts.
6.13.
19.22
[COM] terminals
[COM] terminals to use a contact or NPN transistor.
7
8
9
10
11
Schedule-
select
terminals
SCH 1
SCH 2
SCH 4
SCH 8
SCH 16
Terminal for selection of schedule No.
Functions when the external schedule select is
selected. (Refer to
6.(6)
⑦
SCHEDULE
)
The schedule No is the sum of the SCH Nos. of the
closed terminals. (Refer to Table of schedule Nos.
and corresponding schedule-select terminals.)
12
[PARITY] terminal
Functions when the external schedule select with parity is selected. (Refer
to
6.(6)
⑦
SCHEDULE
)
This terminal permits detection of nonconformance due to disconnection of
the schedule-select signal conductor.
Set so that the sum of the number of closed circuits for the schedule-select
signal conductors and the [PARITY] signal conductor is always an odd
number.
"When setting 2 for schedule No."
Close SCH2 and open the [PARITY] terminal. [The
number of closed circuits is 1.]
"When setting 6 for schedule No."
Close SCH2 and 4, and close the [PARITY] terminal. [The
number of closed circuits is 3.]
14
[PO/CH SEL] terminal
Input terminal for output changeover selection.
(This function is provided only for
MD-B4000B
.)
The direction of the welding current flow when the circuit is open is opposite
to that when the circuit is closed. (Refer to
5.(4)
⑤
Operation of
MD-B4000B
.)
15
[WELD ON/OFF] terminal
When this terminal is opened, the flow of welding current is not allowed
when the weld sequence is started. Use this terminal to tentatively activate
the equipment.
EXAMPLE