MD Series
5. Connection
5-1
5.
Connection
(1) Basic Connection
36
35
3
6
5
2
1
15
16
Short-circuit
in most cases
Power cable (350VA) (option)
WELD ON/OFF
Short-circuit
in most cases
START cable
(option)
Attach to the limit
switch of the head
V SENS cable (option)
Install near the electrode
Secondary cable (option)
Make the cable as short and thick as possible
Terminal board
N
o
p
o
l
a
r
i
t
y
No polarity
No polarity
Connect
green to 35
The most basic connection
37
*2
*2 For safety, be sure to connect one side of the output terminal of the power supply
to ground.
WARNING
*3
*3 Connect the [V SENS] cable though the equipment can be operated without it in the
constant-current control.
If not, refer to 4.(2) ①Control signal terminal strip.
Be sure to connect it in the constant-voltage control or the combination control
of constant-current and constant-voltage.
!
*1
When the ground pin of the power cable
cannot be connected to ground, connect
the ground wire to the ground terminal
located near the ground mark. *1
Summary of Contents for MD-A8000B-05 Series