MD Series
6. Explanation of the Screen
6-5
⑤
③
①
①
②
①
②
①
②
②
[When displaying data of two or less] [When displaying data of three or more]
①
Selected measured item
CURR : AVE ... Displays the average value of current.
CURR : PEAK ... Displays the peak value of current.
VOLT : AVE ...
Displays the average value of voltage.
VOLT : PEAK ... Displays the peak value of voltage.
POWER ...
Displays the average value of power.
RESISTANCE ... Displays the average value of resistance.
②
Grid spacing of waveform (vertical axis)
Displays the grid spacing for vertical axis of each waveform.
③
Grid spacing of waveform (horizontal axis)
Displays the grid spacing for time axis of waveform.
④
Measured value of WE1
Displays the measured value of WE1 welding for each measured value.
⑤
Measured value of WE2
Displays the measured value of WE2 welding for each measured value.
Not displayed when SCHEDULE MODE on the STATUS screen is set to
SINGLE.
⑥
Count
Displays the count of the welding judged good.
When the measured value exceeds the display range, --- is displayed.
To reset the value of GOOD COUNT, input CNTR RESET of the control signal
terminal strip.
(d) CURR
Selects whether to display the waveform of current and the average
value/peal value.
Refer to
(h)
for switching of the average value and the peak value.
①
②
④
⑥
①
④
⑤
②
③
⑤
④
④
⑤
④
⑤
④
⑤
⑥