MD Series
4. Name and Functions of Each Section
4-2
①
Display screen
Displays the welding schedule, welding current monitor value, and other
information.
②
POWER lamp
Comes on when the POWER switch is turned on, the power is supplied, and
the equipment functions normally.
③
START lamp
Comes on when the start signal is input and the sequence starts.
④
READY lamp
Comes on when the welding current is ready to be supplied to the equipment.
The following conditions must be met for this lamp to come on:
・
The WELD lamp on the front panel is on.
・
The WELD ON/OFF terminal of the control signal terminal strip on the rear
panel is closed.
・
No fault is occurring.
・
Not in the middle of welding or charging
⑤
TROUBLE lamp
Comes on when a fault occurs.
⑥
WELD key / WELD lamp
Used to start the sequence without applying the welding current.
The welding current will not flow when this key is pressed and the WELD lamp
goes out.
To turn ON and OFF the WELD key, hold it down for approx. 1 second.
⑦
Cursor key
Moves the cursor on the display screen vertically and horizontally.
⑧
MENU key
Press this key to display the menu screen.
⑨
RESET key
When a fault is displayed, remove the cause and press this key. This will reset
the fault display.
⑩
ENTER key
Used to determine the set values and selected items. Press this key for each
item to determine the changed contents.
⑪
+ key
Press this key to increase the value of the item.
⑫
- key
Press this key to decrease the value of the item.
⑬
POWER switch
Turn this switch on to switch the power on.
Summary of Contents for MD-A8000B-05 Series