MD Series
5. Connection
5-12
●
When the monitor value is outside the setting range or a fault occurs
during welding
・
Communication output time (*1)---------86 ms max.
Communication output of monitor value. Outputs after the start of the end signal
output.
・
Communication output time (*2)---------25 ms max.
Communication output of fault code. Outputs after the end of screen display.
・
Screen display time
The display time varies by screen. Displays the screen after the end of
communication output (*1).
Menu screen ------------------------------50 ms max.
SCHEDULE screen----------------------117 ms max.
MONITOR screen ------------------------181 ms max.
COMPARATOR screen -----------------104 ms max.
PRECHECK screen ---------------------74ms max.
STATUS screen---------------------------50 ms max.
・
Accepting time for fault reset-------------5 ms
The accepting time for fault reset is the time duration until the acceptance of the
fault reset.
For the processing time at fault reset, refer to
9
On the fault reset.
(2ND STAGE)
(END)
(NG,CAUTION)
Start input
Welding current
End signal output
Caution signal output
Screen display time
Communication output time
Accepting time of fault reset
*1
*2
Fault signal,