MD Series
8. Error Code
8-1
8.
Error Code
No.
Name of fault displayed on the screen
Explanation of fault and corrective measures
E01
MEMORY TROUBLE
The schedule and other data saved in the memory are broken down.
Check all set values.
The following are conceivable causes of loss or corruption of data
stored in memory.
・
Strong power noise and electrostatic noise
・
Faults in the supply voltage due to thunderbolts or lightning
conduction
・
Exceed in writing count limit of flash memory
It is convenient to write down set values in case of data corruption or
loss. (Use
11. Schedule Data Table
.)
Initialize the memory by turning the POWER switch ON while
pressing the MENU key. This resets all set values to the factory
values set before shipment. Re-set the values that you recorded on
paper beforehand.
If E01: MEMORY TROUBLE is displayed again, repair is required.
Contact us.
E02
SYSTEM ERROR
An error has been detected in the MD series. Once turn off power
and turn on again.
If E02: SYSTEM ERROR is displayed again, repair is required.
Contact us.
E03
TRIP OF THERMO
The equipment is overheated.
Stop operation, let the equipment to cool off, and press the RESET
button.
E04
NO CURRENT
The welding current is not flowing.
Or the welding current measured value is less than 1.3% of the set
current range.
Check the electrode contact and wiring of the welding head.
If the upslope time is long when the set current value is small, the
indication may appear.
No current is not detected between the start of welding and the time
set for NO CURR MONITOR START.
E05
NO VOLTAGE
The voltage between electrodes is 0.07 V or less.
Or the V SENS cable is disconnected.
Check the condition and position of the V SENS cable connection.
This fault will not be displayed when CURR is selected on
CONTROL setting. (Refer to
6.(6)
CONTROL
.)
No voltage is not detected between the start of welding and the time
set for NO CURR MONITOR START, and during downslope.