MD Series
9. External Communication Function
9-16
5) Specified code No.: S04 (COMPARATOR screen)
Used when SCHEDULE MODE on the STATUS screen is SINGLE.
In case of DOUBLE, use Specified code No. S05.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S04[CR][LF]
MD series -> Host PC
!01008S04: kA, 2.20, 1.80, 0, 1.20, 0.80, 0, 02.2, 01.8 [CR][LF]
A B C D E F G H I
Item
Character
string
Content Range
Increment/
Decrement
A **,
Unit of current value
_A: Current value in A
(
_
indicates space)
kA: Current value in kA
A or kA
-
B
****,
*1
WE: Current upper limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
C
****,
*1
WE: Current lower limit
0000 to 0999[A]
1
*.**,
*2
0.00 to 9.99[kA]
0.01
D *,
Current judgment setting
0: With average value
1: With peak value
0 to 1
1
E
*.**,
WE: Voltage upper limit
0.00 to 9.99[V]
0.01
F
*.**,
WE: Voltage lower limit
0.00 to 9.99[V]
0.01
G *,
Voltage judgment setting
0: With average value
1: With peak value
0 to 1
1
H
*.**,
*1
WE: Power upper limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
I
*.**,
*1
WE: Power lower limit
0.00 to 9.99[kW]
0.01
**.*,
*2
00.0 to 99.9[kW]
0.1
*1: When CURRENT RANGE on the STATUS screen is ***A.
*2: When CURRENT RANGE on the STATUS screen is *.**kA.