Item
Character
string
Content Range
W
****,
*1
PRECHECK:
Current
Peak value
0000 to 0999[A] ,----
*5
*.**,
*2
0.00 to 9.99[kA] ,----
*5
X
****,
*1
Average value
0000 to 0999[A] ,----
*5
*.**,
*2
0.00 to 9.99[kA] ,----
*5
Y
*.**
*3
PRECHECK: Weld time
(Set time)
0.00 to 1.00[ms]
**.*
*4
00.0 to 01.0[ms]
Z
[CR][LF]
CR, LF code
0DH 0AH (fixed)
*1: When CURRENT RANGE on the STATUS screen is ***A.
*2: When CURRENT RANGE on the STATUS screen is *.**kA.
*3: When WELD TIME on the STATUS screen is NORMAL.
*4: When WELD TIME on the STATUS screen is LONG.
*5: When the value exceeds the display range.