MD Series
9. External Communication Function
9-11
Item Command
Code
6
Resetting of fault
# Device No. W or V Schedule No.
Specified code No. : Data
Ex.: Reset the fault of Device No. 01.
Host PC -> MD series
# ID1 ID2 W SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
#01W000S13: E00[CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01001S13: E00[CR][LF]
・
Write 000 for Schedule No. (SH1, SH2, SH3).
・
Write S13 for Specified code No. (CD1, CD2, CD3).
・
Schedule No. for data output from the MD series becomes last-welded Schedule No.
・
E00 is output for data.