MD Series
8. Error Code
8-2
No.
Name of fault displayed on the screen
Explanation of fault and corrective measures
E06
OUT LIMIT OF CURRENT
The measured value of welding current has been outside of the
monitor range set on the COMPARATOR screen.
E07
OUT LIMIT OF VOLTAGE
The measured voltage between electrodes has been outside of the
monitor range set on the COMPARATOR screen.
E08
OUT LIMIT OF POWER
The measured welding power has been outside of the monitor range
set on the COMPARATOR screen.
E12
CHARGE TROUBLE(LACK)
Failure of charging circuit.
This message appears when charging is not completed within 7
seconds after power is turned on.
Turn off the power immediately and contact us or your distributor.
E13
CHARGE TROUBLE(OVER)
Failure of the charging circuit.
Displayed when the charging voltage is too high.
Turn off the power immediately and contact us or your distributor.
E14
TRANSISTOR TROUBLE
Fault of the welding control circuit.
Welding current is output continuously.
Turn off the power immediately and contact us or your distributor.
E15
PRECHECK ERROR
Displayed when the current exceeds the upper or lower limit of the
current range set on the PRECHECK screen when the precheck
weld is used.
Check the contact of electrodes and the state of the weldment.
E16
ABORT
The jumper wires between No.1 and No.3 (STOP) of terminals on
the rear panel are disconnected.
E17
START PARITY ERROR
Displayed when a parity error occurs during operation with
SCHEDULE# set to EXT.(P). (Refer to
6.(6)
SCHEDULE
.)
E18
COUNT MEMORY TROUBLE
Counts of GOOD COUNT are damaged.
The following are conceivable causes of damage of counted data.
・
Strong power noise and electrostatic noise
・
Faults in the supply voltage due to thunderbolts or lightning
conduction
・
Decrease in voltage of battery for memory backup
E19
VOLT SENS ERROR
The V SENS cable is broken or disconnected.
Confirm the connection of the V SENS cable.
When the V SENS cable is not connected in the constant-current
control, short on Terminals 36 and 37.