MD Series
5. Connection
5-15
6
On the polarity-switching signal (MD-B4000B only)
●
Screen other than SCHEDULE screen
Input the polarity-switching signal 10 ms or more before start signal.
●
SCHEDULE screen
Input the polarity-switching signal 56 ms or more before the start signal.
The display of the schedule waveform on the SCHEDULE screen is changed.
7
On the fault reset
・
Screen display time---------------------------212 ms max
・
Start-waiting time ------------------------------5 ms
Accepts a start after the start-waiting time.
(2ND STAGE)
Start input
(PO/CH SEL)
Polarity-switching select input
56ms
56ms
(ERR RESET)
Fault reset input
Start-waiting time
Screen display, Processing time
(2ND STAGE)
Start input
(PO/CH SEL)
Polarity-switching select input
16ms
16ms
Summary of Contents for MD-A8000B-05 Series