MD Series
9. External Communication Function
9-10
Item Command
Code
3
Writing of data (with data storage)
# Device No. W Schedule No. Specified
code No. : Data
Ex.: Write Schedule No. 8 of Device No. 01 and data of Specified code No. S01.
Host PC -> MD series
# ID1 ID2 W SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
#01W008S01: Data [CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01008S01: Data [CR][LF]
・
See
Data code table for the data order.
4
Writing of data (without data storage)
# Device No. V Schedule No. Specified
code No. : Data
Ex.: Write Schedule No. 8 of Device No. 01 and data of Specified code No. S01.
Host PC -> MD series
# ID1 ID2 V SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
#01V008S01: Data [CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01008S01: Data [CR][LF]
・
See
Data code table for the data order.
・
When the power is turned off, the written data is cleared.
・
When Specified code No. S03 is written, the data is saved.
・
When the data is changed by panel operations after data saved, the data is saved.
・
To hold the written data even after the power is turned off, use the Writing of data
(with data storage).
5
Reading of fault data
# Device No. R Schedule No. Specified
code No.
Ex.: Read fault data of Device No. 01
Host PC -> MD series
# ID1 ID2 R SH1 SH2 SH3 CD1 CD2 CD3 [CR] [LF]
#01R000S13[CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01001S13: Data [CR][LF]
・
Write 000 for Schedule No. (SH1, SH2, SH3).
・
Write S13 for Specified code No. (CD1, CD2, CD3).
・
See
Data code table for the data order.
・
Schedule No. for data output from the MD series becomes last-welded Schedule No.
Summary of Contents for MD-A8000B-05 Series
Page 95: ......