MD Series
6. Explanation of the Screen
6-15
○
22
COMMUNICATION MODE
Selects a communication mode. Valid when COMMUNICATION CONTROL is
set to DATA OUTPUT.
B MODE
Performs the same one-way communication.
C MODE
Adds the weld time, monitor value of precheck welding,
etc. to B MODE and performs the one-way communication.
For contents output in communication, refer to
9. External Communication
Function
.
○
23
COMMUNICATION UNIT#
Inputs the device No. (ID#). The range is 01 to 31.
When performing the two-way communication between two or more devices,
assign one device No. for one device.
○
24
COMMUNICATION SPEED
Selects a communication speed.
9600
Communication at 9600 bps
19200
Communication at 19200 bps
38400
Communication at 38400 bps
When the communication cannot be performed well, slow down the use a
communication speed.
○
25
BACK
Moves to the STATUS (2/2) screen.
○
26
ERROR SETTING
The signal output when an error occurred (trouble/caution signals) can be set
for each item.
Error code
Contents
E04: NO CURRENT
No current
E05: NO VOLTAGE
No voltage
E06, E09: OUT LIMIT OF CURR
Fault of current
E07, E10: OUT LIMIT OF VOLT
Fault of voltage
E08, E11: OUT LIMIT OF POWER
Fault of power
E15: PRECHECK ERROR
Precheck error
E18: COUNT MEMORY TROUBLE
Count memory trouble
E20: CYCLE TROUBLE
The start signal is turned off during
welding.