![Amada MD-A8000B-05 Series Operation Manual Download Page 31](http://html1.mh-extra.com/html/amada/md-a8000b-05-series/md-a8000b-05-series_operation-manual_2915803031.webp)
MD Series
5. Connection
5-11
4
On the screen display time and communication time (Common to MD series)
●
When the monitor value is within the setting range or a fault does not
occur during welding
・
Communication output time ----------------86 ms max.
Communication output of monitor value. Outputs after the start of the end signal
output.
・
Screen display time
The display time varies by screen. Displays the screen after the end of
communication output.
Menu screen --------------------------------14 ms max.
SCHEDULE screen------------------------80 ms max.
MONITOR screen --------------------------145 ms max.
COMPARATOR screen -------------------66 ms max.
PRECHECK screen -----------------------37 ms max.
STATUS screen-----------------------------14 ms max.
When the start is input while the MONITOR screen is displayed, the screen
display is canceled to accept the next start. The next start is accepted 5 ms after
the communication output ends. When the screen display is canceled to accept
the start, the start stability time is [START SIG.TIME s 5 ms maximum].
・
Start-waiting time ------------------------------5 ms
The start-waiting time is the time duration required to turn off the start input.
Also, the status does not change until the start-waiting time is turned off even if
the input signal such as schedule, polarity-switching, channel-switching, etc. is
changed.
(2ND STAGE)
(END)
(GOOD)
Start input
Welding current
End signal output
Normal signal output
Screen display time
Start-waiting time
Communication output time